MetiSmile-MR is a facial scanner equipped with the capability to record mandibular movement trajectories. This groundbreaking innovation enables the simple and precise capture of both 3D facial data and dynamic occlusion using a single device.

Powered by a robust software platform, MetiSmile-MR seamlessly integrates intraoral, facial, jaw motion, and CBCT data—delivering a comprehensive solution that unites aesthetics and functionality in digital dental treatment.

  • Jaw Motion

  • Facial Aesthetic Analysis

  • Orthodontic Facial Simulation

  • Digital Smile Design ( Upcoming )

Powerful Software for Virtual Patient Creation

Intraoral Data
Facial Data
Mandibular Movement Trajectory
CBCT Data
Benefits
Supports direct DICOM data segmentation and auto-alignment
Multi-modal data aligned and analyzed in one coordinate system
Compatible with exocad software
  1. Design

  2. Fabricate (Lab or In-house)

Mandibular Movement Trajectory Tracking (Standard)

Mandibular Movement Trajectory Analysis (Optional)

Optimal Jaw Relation Determination (Optional)

  • Mandibular Movement Trajectory Tracking (Standard)
    By accurately capturing the patient's mandibular movement with MetiSmile-MR and integrating intraoral scan data, digital dynamic occlusal contacts can be obtained. This helps identify and eliminate premature occlusal contacts, enabling long-term, stable restorative outcomes.

    Mandibular Movement Trajectory Tracking

    (Standard)

  • Mandibular Movement Trajectory Analysis (Optional)
    This feature offers a comprehensive view of condyle and incisal edge motion in different directions, unlocking the power of real-time 3D visualization with integrated CBCT data. By projecting these movements onto standard 2D anatomical planes, it enables precise evaluation of movement coordination, occlusal symmetry, and stability. This supports accurate diagnosis and treatment planning for TMD patients.

    Mandibular Movement Trajectory Analysis

    (Optional)

  • Optimal Jaw Relation Determination (Optional)
    This function quickly identifies the most suitable jaw relation. For dentulous patients, it aids in the creation of splints for occlusal rehabilitation. For edentulous cases, the confirmed optimal occlusal position supports denture fabrication and streamlines the entire workflow.

    NOTE: This module is suitable for the patients without TMD (Temporomandibular Disorder) only.

    Optimal Jaw Relation Determination

    (Optional)

  • FACIAL AESTHETIC ANALYSIS

    The intuitive software is capable of recognizing 3D facial features. The advanced facial planning tool enable real-time facial contour adjustments for personalized treatment plans.

    Measurement and comparison tools automatically identify key facial planes and points, providing templates for facial proportion analysis and comparing pre-and post-treatment changes.

    These features help dentists diagnose, evaluate, and improve treatment outcomes while enhancing patient satisfaction with visual representations.

  • ORTHODONTIC FACIAL SIMULATION

    The orthe simulation inodule can simulate changes in both teeth and face during orthodontic treatment,allow patients to preview post-treatment effects, This is extremely helpful for consultations between patients and dentists.

Technical Specifications

Model MetiSmile - MR
Resolution Data Acquisition Camera: 1.3 Mega Pixel
HD Texture Camera: 5.0 Mega Pixel
Accuracy 50μm
Field of View With working distance 500mm, the FOV is 210*270mm
Output Format PLY, OBJ, STL
White LED color temperature 5500K
Dimension 215*50*75mm
Weight 800g
Power Supply Input: AC100-220V~, 50/60HZ, 1.5A
Output: DC12V, 7.0V

Recommended PC Configuration

CPU Intel Core i7-8700 or higher
Memory 16GB is the minimum, 32GB is highly recommended.
Hard Disk Drive 256GB SSD or above
Display Resolution 1920*1080, 60Hz or higher
Connector USB 3.0
Graphic Card (GPU) NVIDIA RTX 2060 6GB or higher
Operating System Microsoft Windows 10(64-bit)or later versions of
Windows operating system

FAQ

Q1:Can MetiSmile-MR be purchased and used independently?
MetiSmile-MR can be purchased as a standalone device or used in combination with the all-in-one cart system, depending on your clinical workflow needs.
Q2:What is the major difference between MetiSmile and MetiSmile-MR?
MetiSmile-MR is specifically designed for jaw motion function. It comes with a built-in Mandibular Movement Trajectory Tracking module. Users can also optionally purchase and activate Mandibular Movement Trajectory Analysis and Optimal Jaw Relation modules. Other functionalities are identical to the standard MetiSmile.
Q3:What accessories are required to use jaw motion features, and how can I obtain them?

• Cement Retention Jaw Motion Trackers (for natural teeth or removable dentures cases)

• Screw Retention Jaw Motion Trackers (for All-on-X implant cases)

• Markers

Each tracker consists of a metal tracker body (reusable for up to 100 sterilization cycles) and a geometric-featured shell (reusable for up to 50 cycles). Additional accessory kits can be purchased through your local distributor.

Q4:What can I do with the trajectory data acquired by the software?
Trajectory files can be exported to exocad to assist in designing prosthetic restorations. These data can also support the analysis of TMD by visualizing movement coordination, occlusal symmetry, and stability, but final diagnosis remains at the discretion of the clinician. The software also helps to find the most suitable jaw relationship for both dentulous and edentulous patients. Adjusted jaw relations can be imported into exocad or CreSplint within the software for accurate occlusal splint design.
Q5:Can I continue scanning if the markers or motion tracker fall off during the capture process?
If the markers or the motion tracker become detached, simply reattach them to their original positions. The software supports re-recognition, allowing you to resume the capture process without restarting.