Skip to content

MetiSmile

A Functional and Aesthetic Prosthetic Solution

 

Overview

Face Scanner & Mandibular Movement Tracking System

37C3B8FC-60CF-40FA-B16F-672775DEA9FF

Jaw Motion

面扫网页-14

Facial Aesthetic Analysis

面扫网页-15

Orthodontic Facial Simulation

面扫网页-16

Digital Smile Design

E6613A3A-7E66-46C9-A52A-A2490EDACEE4

Differences

MetiSmile: Does not include Jaw Motion Modules by default. Modules can be purchased separately if needed.

 

MetiSmile-MR: Comes standard with the Jaw Motion Module – Mandibular Movement Trajectory Tracking.

Optimal Jaw Relation Determination and Mandibular Movement Trajectory Analysis can be purchased separately if needed.

Powerful Software for Virtual Patient Creation

 

930356B6-DEEB-4966-84C4-232C22470DB1

Benefits

  • Supports direct DICOM data segmentation and auto-alignment

  • Multi-modal data aligned and analyzed in one coordinate system
     
  • Compatible with exocad software

Mandibular Movement Trajectory Tracking

By accurately capturing the patient's mandibular movement with MetiSmile-MR and integrating intraoral scan data, digital dynamic occlusal contacts can be obtained. This helps identify and eliminate premature occlusal contacts, enabling long-term, stable restorative outcomes.

Mandibular Movement Trajectory Analysis

This feature offers a comprehensive view of condyle and incisal edge motion in different directions, unlocking the power of real-time 3D visualization with integrated CBCT data. By projecting these movements onto standard 2D anatomical planes, it enables precise evaluation of movement coordination, occlusal symmetry, and stability. This supports accurate diagnosis and treatment planning for TMD patients.

Optimal Jaw Relation Determination

This function quickly identifies the most suitable jaw relation. For dentulous patients, it aids in the creation of splints for occlusal rehabilitation. For edentulous cases, the confirmed optimal occlusal position supports denture fabrication and streamlines the entire workflow.
NOTE: This module is suitable for the patients without TMD(Temporomandibular Disorder)only.

Facial Aesthetic Analysis

The intuitive software is capable of recognizing 3D facial features.The advancedfacial planning tool enable real-time facial contour adjustments for personalized treatment plans.

 

Measurement and comparison tool sautomatically identify key facial planes and points, providing templates for facial

 

proportion analysis and comparing pre-and post-treatment changes.

 

These features help dentists diagnose, evaluate, and improve treatment outcomes while enhancing patient satisfaction with visual representations.

Orthodontic Facial Simulation

The orthe simulation inodule can simulate changes in both teeth and face during orthodontic treatment, allow patients to preview post-treatment effects, This is extremely helpful for consultations between patients and dentists.

ConsulDSD Smile Design

ConsulDsD enables precise and artistic smile designs within minutes. Unlike flat, front-view 2D images, it lets patients to preview their potential esthetic outcome from a true 3D perspective.

 

This powerful visualization deepens patient understanding of their treatment possibilities, streamlines clinical communication, and makes decision-making faster and more confident.

 

 

MetiSmile Specs

  • Resolution Data Acquisition Camera: 1.3 Mega PixelHD Texture Camera: 5.0 Mega Pixel
  • Accuracy 50μm
  • Field of View With working distance 500mm, the FOV is 210*270mm
  • Output Format PLY, OBJ, STL
  • White LED color temperature 5500K
  • Dimension 215*50*75mm
  • Weight 800g
  • Power Supply Input: AC100-220V~, 50/60HZ, 1.5AOutput: DC12V, 7.0V

Recommended PC Configuration

  • CPU Intel Core i7-8700 or higher
  • Memory 16GB is the minimum, 32GB is highly recommended.
  • Hard Disk Drive 256GB SSD or above
  • Display Resolution 1920*1080, 60Hz or higher
  • Connector USB 3.0
  • Graphic Card (GPU) NVIDIA RTX A2000, GDDR6, 12GB
  • Operating System Microsoft Windows 10(64-bit)or later versions ofWindows operating system

 

Frequently Asked Questions

  • What is the major difference between MetiSmile and MetiSmile-MR?

    Metismile-MR is specifically designed for jaw motion function. lt comes with a bult in Mandibular Movement Trajectory Tracking module. The standard MetiSmile does not include jaw motion modules and requires separate purchase. Other functions remain the same for both versions.
  • Are the accessories the same for MetiSmile and MetiSmile-MR?

    No. MetiSmile-MR includes jaw motion tracking by default, so it comes with additional motion trackers and markers. The standard MetiSmile package includes markers only.
  • What can I do with the mandibular trajectory data?

    Trajectory data can be exported to exocad for prosthetic design.

    It also supports evaluation of movement coordination, symmetry, and stability for TMD analysis (final diagnosis is clinician-dependent).Optimized jaw relations can be transferred to exocad or CreSplint for accurate splint design.

  • Are facial scan data open and compatible with third-party software?

    Yes. MetiSmile exports STL, OBJ, and PLY formats and is fully compatible with exocad and other third-party software.
  • What is the clinical value of using a face scanner for edentulous implant restoration?

    Facial scanning creates an accurate 3D virtual patient by integrating facial, intraoral, and CBCT data. It ensures proper jaw relation and facial support, improves communication with patients and labs, captures details 2D photos cannot, and helps reduce remakes while increasing efficiency and patient satisfaction.